Three-phase AC cage induction motor forward and reverse circuit trouble shooting method is as follows: ** 1. Trouble Shooting for Broken Circuit ** 1. ** Initial Examination ** - Close the main power switch of the main circuit of the motor and press the forward start button. If the motor does not rotate, check the fuse and power supply for faults first before the motor is burned. Check the main circuit and control circuit. - After eliminating the fuse and power failure, the main contact of the contactors can be manually closed because the motor is controlled by the contactors to lose power. If the motor turns, it means that the open circuit fault occurs in the control circuit instead of the main circuit. 2. ** Control circuit check ** - Cut off the fuse of the control circuit and the power supply of the main circuit, and check the connection with a Multimeter. Put the Multimeter in front of the thermal relay, one probe on the KM1 coil, press the start button, and the value should be zero; put the other probe on the other end of the KM1 coil, and the value should be the resistance value of the coil of the contactors. The reversing circuit was also checked in this way. - If the value in the circuit shows infinity, there is a break point. At this time, it is necessary to gradually check whether the button, the auxiliary contact of the contactors, and the connection of the wires are loose. ** 2. Short Circuit Trouble Checking ** - In the control circuit, it was mainly to check the short circuit of the contacts of the same electrical appliances and the contacts between different electrical appliances. This was the common fault location of the control circuit. For the positive and reverse control circuit, the button generally does not have a short-circuit problem. The main check is the auxiliary contact of the contactors. Use a universal meter to check the connection and break to determine whether there is a short-circuit fault in the positive and reverse circuit. ** 3. Fault diagnosis of the motor's phase-loss operation ** - When the motor speed is far lower than the rated speed and the heat is serious, it may be in a phase loss state. The power supply of three-phase induction motor is 380V, and the voltage between two of the three phases is 380V. Multimeter can be used to measure the voltage to accurately determine which phase of the ADC is broken, and clamp current meter can also be used to measure the three-phase current of three-phase induction motor. Under normal circumstances, the three-phase currents are similar. If the current of a certain phase is extremely low, it can be judged that it is a phase loss. Commonly used fault analysis methods included resistance grading measurement method and low-voltage test pen measurement method. It was also possible to determine the fault range based on the circuit diagram with logic analysis method, and use the resistance grading measurement method to find the fault point and eliminate the fault. Read more exciting novels for free
The following is an explanation of the principle of alternating forward and backward rotation of the motor: ##I. Explanation of the principle analysis diagram based on the relay control circuit 1. * * Main circuit part ** - Main switch QF: It is the main switch of the main circuit and the control circuit, mainly used to isolate the power supply and short-circuit protection. - AC contactors KM1 and KM2 main contacts: connected in series in the main circuit, switched on and off to control the positive and negative rotation cycle of the motor. For example, when the KM1 main contact is closed, the motor receives a power input of a phase sequence and turns forward; when the KM2 main contact is closed, the motor receives a power input of a changed phase sequence and turns backward. 2. * * Control circuit part ** - "Relay KC: After pressing the start button, the KC coil is energized, and its normally open contact is closed and locked in the closed position. This is the start of the entire control circuit. - Time Relays KT1 and KT2: - When the KC normally open contact is closed, the KT1 and KM1 coil circuits are connected. The main contact of KM1 is closed to make the motor rotate forward, and the normally closed contact of KM1 is opened (in the coil circuit of KM2) to prevent the reversing contactors from getting electricity when the motor is rotating forward. KT1 was connected in series to the delay contacts of the KM1 and KM2 coil circuits, and the timer started. - When the KT1 delay contact reaches the set time, the delay break contact is opened to cause the KM1 coil to lose power (the main contact of the forward rotating contactors is opened), and the delay close contact is closed. At this time, the KM2 coil and the time relay KT2 coil are energized, the KM2 main contact is closed, and the motor is reversed. The KM2 normally closed contact is opened (in the KM1 coil circuit) to prevent short circuit. - Then, KT2 was connected in series with the time relay delay break contact of the KT1 coil circuit to start timing. When the KT2 delay break contact reached the set time, the KT1 coil lost power, and the two delay contacts of KT1 were reset. Then, the KM2 and KT1 coil lost power, and the KM2 main contact was disconnected. After the relevant contacts were reset, the AC contractor coil KM1 and the time relay KT1 coil were energized again, and so on. ##II. Explanation of the principle analysis diagram of the control system (ladder diagram) 1. * * Forward Rotation Control ** - Press the forward start button, SSB2 (in the ladder diagram, the corresponding X0 turns on), and its normally open contact is connected. The coil of Y0 is "energized" and self-protected, which makes the coil of KM1 energized and the motor starts to rotate forward. Here, the normally closed electric shocks of Y0 and Y1 were connected in series with each other's coil to form an interlocked loop, ensuring that the coil of KM1 and KM2 would not be energized at the same time. 2. * * Reverse Control ** - When the motor is rotating forward (Y0 is on), if you directly press the reverse start button SSB3 (X1 becomes on), the normally closed contact of X1 will be disconnected, causing the Y0 coil to "lose power". At the same time, the normally open contact of X1 will be connected, causing the Y1 coil to "gain power", and the motor will turn from forward to reverse. 3. * * Interlocking mechanism ** - In the ladder diagram, in addition to connecting the normally closed contact of Y0 and Y1 to the coil of the other party in series (called "electrical interlocked "), there was also a" button interlocked ". The normally closed contact of the reverse start button X1 was connected in series with the coil of Y0 that controlled the forward rotation, and the normally closed contact of the forward start button X0 was connected in series with the coil of Y1 that controlled the reverse rotation. This double interlocked ensured the safety and reliability of the forward and reverse rotation control. ##III. Explanation of the principle analysis diagram based on the double interlocked positive and negative rotation control circuit (double interlocked contactors and buttons) 1. * * Forward Rotation Start ** - Press the start button of the SSB1 forward rotation, and its break contact will first break the reverse circuit to realize the button interlocked, and then its contact will close, and the KM1 coil will be energized. The KM1 break-off auxiliary contact first breaks the reverse circuit to realize the mutual locking of the contactors, then the KM1 break-on auxiliary contact and the KM1 main contact are closed at the same time to realize the self-locking, and the motor is energized to rotate forward. 2. * * Reversal activated ** - Directly press the reverse start button of the SK2, and the break contact will first break the forward circuit to realize the button interlocked, and then the contact will be closed, and the KM2 coil will be energized. The KM2 movable break auxiliary contact first breaks the forward rotation circuit to realize the mutual locking of the contactors, then the KM2 movable close auxiliary contact and the KM2 main contact are closed at the same time to realize the self-locking, and the motor is energized to reverse. 3. * * Stop Operation ** - Press the stop button of the SSB3, and the motor will stop running. The double-interlocked circuit overcame the shortcoming that the stop button needed to be pressed when the positive and negative reversing control circuit of the interlocked contactors switched over. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>
Not all single-phase motor could achieve positive and negative rotation. For example, shaded pole motor, submerged pump motor, etc., due to their special use, although some of them had a capacity, they would be modified during use, such as adding one-way bearings, reversing sleeves, etc. These motor could not rotate forward and backward. In principle, double-capacity and single-capacity motor could achieve positive and negative rotation. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>
For a 48V shunt-excited direct current motor (the motor junction box has four terminal blocks, two excitations, and two armatures), as long as the switch is used to change the voltage of the armatures, the direction of the motor can be changed. The following methods could also be used: 1. If it was manually controlled, a mechanical switch could be used to realize the forward and reverse rotation of the motor. A double-pole double-throw switch could be used. The connection method was as follows: When the switch was turned up, the A pole of the direct current motor was connected to the true voltage of 48V, the B pole was connected to the ground voltage of 48V, and the motor was rotated forward (reverse). When the switch was turned down, the B pole of the direct current motor was connected to the true voltage of 48V, the A pole was connected to the ground voltage of 48V, and the motor was rotated backward (forward). 2. A two-way relay was used to realize the positive and negative rotation of the direct current motor. When the relay is not working, the A pole of the direct current motor is connected to Vac (48V), the B pole is connected to Ground, and the motor is rotating forward (reverse); when the relay is connected, the B pole of the direct current motor is connected to Vac (48V), the A pole is connected to Ground, and the motor is rotating backward (forward). 3. The positive and negative rotation circuit was formed by two relay (each relay had three contacts, normally open, normally closed and public, respectively. The action of each group of contacts was controlled by two groups of coil). The positive and negative rotation of the motor was realized by controlling the power supply and power failure of the two groups of coil: - When the two sets of coil are cut off, the motor is in a stopped state; - When the first group of coil is energized and the second group of coil is de-energized, the current loop is formed to make the motor rotate forward; - When the second group of coil is energized and the first group of coil is de-energized, the current loop is formed to cause the motor to rotate in reverse; - When both sets of coil were energized, the motor stopped. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>
The delayed positive and negative rotation of the motor had applications in many practical scenarios: 1. ** Large washing machine **: It can use a positive and negative automatic controller to control the motor to achieve the positive and reverse functions. The reversing automatic controller was a double-pulse delay relay, suitable for control circuits with an AC of 50HZ and a rated voltage of 380V and below. It controlled the motor to rotate forward, stop, and reverse according to the predetermined time. There were two common models with a fixed stop time for forward and reverse rotation (such as 25 seconds for forward rotation, 5 seconds for stop, and 25 seconds for reverse rotation), and an variable stop time for forward and reverse rotation (forward rotation, reverse rotation, and stop can be set within 1 - 15 minutes). 2. ** Mechanical Equipment Control **: The delayed switching of the forward and reverse rotation of the motor is often used to control mechanical equipment. It can use the motor forward and reverse control module, which is composed of a power supply module, a control module, and a motor drive module. After connecting the power supply, the motor, and the control module and setting the parameters of the control module, the automatic switching of the positive and negative rotation of the motor and the delay control could be realized. It was also possible to use a single-chip computer to control the forward and reverse rotation of the motor. First, the motor drive module was connected to the single-chip computer controller, and then the control program was written. This could achieve more flexible control, and the control program could be designed according to needs. When switching between the positive and negative rotation of the motor, the following techniques should be paid attention to: - ** Setting of delay time **: Set it according to the equipment requirements, usually 1 - 5 seconds, to ensure the stability and safety of the equipment. - ** Selection of the motor drive module **: Consider the parameters such as the motor power and voltage to ensure the accuracy and stability of the motor's forward and reverse rotation control. At the same time, pay attention to the quality and reliability of the motor drive module to ensure the long-term stable operation of the equipment. - ** Controller's reliability and stability **: The controller is the core part, and its reliability and stability affect the operation and safety of the equipment. The quality and reliability should be taken into consideration when choosing, and it should be fully tested and verified. 3. ** Control of specific actions in the motor control **: For example, when controlling the stepping motor, press the start switch to trigger the cylinder to push out and maintain for a certain time (such as 2s), and then the motor will rotate forward. When it touches the sensor, it will slow down and stop. When the motor stops, it will trigger the cylinder to retract and maintain for a certain time (such as 3s), and then the motor will rotate backward. When it touches the sensor, it will stop urgently. This involved the use of multiple instructions, including adding wait for input instructions, triggering output instructions, delaying wait instructions, and so on. 4. ** Three-phase motor positive and negative transfer wire control **: The positive and negative transfer wire of the three-phase motor can control the positive and negative rotation of the motor by pressing the forward or reverse button, using the buttons, coil, and normally closed contacts in different circuits. During this process, a certain delay can be set through the relevant control circuit. 5. ** In some conventional control scenarios of the motor, such as using a delay relay to realize the functions of the motor's timed start, stop, and forward and backward rotation control. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>
Taking a three-phase motor as an example, a positive and negative rotation control circuit with a timer was as follows: First of all, there are contactors in the circuit. When the main contact of the KP contactors is closed, the motor will rotate forward. When the main contact of the KP contactors is closed, the motor will rotate in reverse. This is because changing the phase sequence of the three-phase motor will change the direction of the rotating magnetic field, which will cause the direction of the motor rotation to change. In this circuit, the timer played the role of controlling the forward and reverse switching time of the motor and the rest time. Take the power-on delay time relay as an example. Suppose you press the forward start button (such as sb2) first, kme will attract and self-lock to make the motor rotate forward. At this time, the timer kt1 will start to power-on and delay (for example, set five seconds). After five seconds, the contact of kt1 will move, open and close, making km2 attract (km1 release). The motor will switch to reverse direction. At the same time, km2 attracts and makes the kt2 coil receive electricity and start to delay (assuming it is also five seconds). After five seconds, the electric shock action of kt2 will be disconnected, km2 will release, and the motor will stop. Then, the timer kt1 was powered up again and delayed. After the time was up, km1 pulled the motor forward again, and so on. In the actual connection, attention should be paid to the connection order and interlocked relationship between the various components. For example, the positive and negative rotation interlocked to prevent the two contactors from short-circuit and other faults caused by the simultaneous attraction. At the same time, it was also necessary to consider the power transmission, self-locking, control logic and other factors of the circuit. However, this was only a basic principle of a motor with a timer. The actual application scenarios were different, and the circuit might be more complicated and required to follow electrical safety regulations for wire operation. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>
The steps to transform a three-phase induction motor into a single-phase motor were as follows: 1. Check the motor: Check whether the three-phase induction motor is suitable for modification. Because the three-phase induction motor usually has three coil, and the single-phase motor only has one coil, it is necessary to carefully check whether the coil of the motor can be re-routed into the coil required for the single-phase motor. 2. Changing the coil: If the motor is suitable for modification, you need to use professional tools and equipment to rewire the coil. This operation usually requires a professional to complete, and the motor must be disassembled before changing the coil. 3. Replacing the Condenser: Single-phase motor needs a transformer to start and run, so it is necessary to choose a suitable transformer according to the power and rated voltage of the motor. 4. Reassemble the motor: After the modification, clean all parts of the motor and reassemble the motor after ensuring that all parts are installed correctly. 5. Test the motor: connect the motor to a suitable power source and check the motor's operation to ensure that it can operate normally. Three-phase motor has star connection and triangle connection. When changing to single-phase operation, two sets of coil will participate in the operation (may be connected in series or in parallel). The maximum power will not exceed two-thirds of the rated power of the three-phase motor. The other set of coil will be mainly combined with the transformer as the starting coil, and there will be a "couple" with the main coil on the circuit. As long as the transformer is selected appropriately, the starting and operation effect of the single-phase motor can be achieved. For example, one connection method is that the three terminal posts of the original three-phase motor are not moved. U1 and V1 can be connected to the live line and neutral line, W1 can be connected to one end of the capacity, and the other end of the capacity can be connected to U1 or V1 (according to the steering requirements). <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>
There were many types of single-phase induction motor winding: ** I. Resistor-start or condenser-start motor's stators winding ** 1. ** Winding Form ** - Most of them use concentric or chain winding. 2. ** The distribution of the two winding ** - The working winding occupies 2/3 of the total slots (120° phase belt), and the starting winding occupies 1/3 of the total slots (60° phase belt). The number of turns of the starting winding is small, generally 1/2 - 1/3 of the number of turns of the working winding, and the cross-section of the wire is 1/2 - 1/3 of the working winding. For example, when the total number of slots in the stators is 24, 2P = 4 (P is the number of pole pairs), the number of slots per pole and phase of the working winding q1= 2q/3 = 4 slots, and the number of slots per pole and phase of the starting winding q2 = q/3 = 2 slots (where q = Z/2Pm, Z is the number of slots in the stators, m is the number of phases, and m = 1 for single-phase machines). 3. ** Pattern of Embedding Lines ** - The main winding was embedded first, and then the auxiliary winding was embedded. The main winding (close to the frame) was below, and the auxiliary winding (close to the rotor-side) was above. ** II. Condenser single-phase induction motor winding ** 1. ** Winding Form ** - The single-layer uses the cross winding, and the double-layer uses the lap winding. 2. ** The distribution of the two winding ** - The main and secondary winding each occupied half of the total number of slots in the stators, which meant that they were both 90° phase belts. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>
Yes. The phase sequence of the three-phase alternating current could be determined by the phase sequence meter. The light on the phase sequence meter turned clockwise, which was the positive phase sequence, and vice versa. Moreover, when two systems with the same voltage level and frequency but from different power sources are in parallel, if the potential difference between the two power sources is measured, the two ends of the voltage meter (or voltage transformer) are connected to the A phase of the two power sources, and then the voltage of the two B and C phases is measured. If these three voltage are not zero, it means that the phase order is different and there may be a reverse phase order. In addition, in some special situations, such as circuit connection errors, it may also cause phase sequence reversal. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>