webnovel
The reverse infiltration system forgot to turn off the high-pressure pump.

The reverse infiltration system forgot to turn off the high-pressure pump.

2026-11-23 00:41
1 answer

If the reverse infiltration system forgot to turn off the high-pressure pump, a series of problems could occur. If the raw water was insufficient, the high-pressure pump could be damaged if it was idling. If the water source is sufficient, if there are conditions in the system such as the reverse infiltration water pressure is less than 0.1MP or greater than 1.5MP, the water PH value is less than 4 or greater than 11, the water residual chorine is greater than 0.1MP/L, the water turbid is greater than 1NTU, and the instrument compressed air pressure is less than 0.4MP, the high-pressure pump may trip. In addition, if it was operated for a long time, the membrane might be blocked due to poor water quality, many local impurities, long time without replacing the filter element or cleaning the reverse infiltration membrane, etc., which would increase the pressure in the pipeline and may cause the pipeline to burst. At the same time, if the pressurizing pump and the high-pressure pump did not work normally, there might be problems related to voltage, wire loosening, reversal, etc. It was necessary to check whether the relay connected to the high-pressure pump was tightly connected, whether the wire of the connecting bolt was loose or fell off, and if the water shortage indicator light flashed, it was necessary to check whether the raw water was sufficient. If it is found that the pressurizing pump and the 220V voltage pump do not turn over, open the exhaust valve of the pump or fill the pump casing with water; if the pressurizing pump and the high-pressure pump turn over under the 380V voltage, replace two of the three power supply terminal. Read more exciting novels for free

Level 2 reverse infiltration plus edi high purity water system

The two-stage reverse infiltration and edi high-purity water system was a high-efficiency pure water production system. In terms of pre-treatment, raw water (such as tap water, underground water, river water, etc.) first went through pre-treatment equipment such as a Quartz Sand filter, an activated carbon filter, etc. The purpose was to remove suspended solid, colloid solution, particles, and other substances in the water to provide qualified water for the subsequent reverse infiltration device. For the secondary reverse infiltration part, when the raw water TDA is greater than 300pm, the secondary reverse infiltration system can be used. The feed water's pH should be controlled between 8.5 - 9.0. When adding NaOH into the feed water, pay attention to the LSI value of the reverse infiltration concentrated water to prevent scaling. The water after the first level of reverse infiltration was further filtered by the second level of reverse infiltration. In the EDI module, generally, the secondary reverse infiltration (RO) pure water was used as EDI feed water. EDI sandwiched ion exchange resin between the negative and positive ion exchange membranes to form EDI units. Driven by direct current, the positive and negative ions in the water flow through the freshwater chamber passed through the negative and positive ion exchange membranes and entered the concentrated water chamber to remove ions in the freshwater chamber. The water in the concentrated water chamber carried the ions out of the system to become concentrated water. During the EDI process, there was no need for regeneration and no acid or alkali-free waste water was discharged. The production would not be affected by the regeneration, and the quality of the produced water would be more stable. The electrical resistance of EDI pure water can be as high as 18M Omega.cm(25 ° C), which is suitable for the preparation of pure water with electrical resistance requirements of 1 - 18.2 M Omega.cm(25 ° C). In the entire system, various parts worked together, such as the 20 tons/hour secondary reverse infiltration +EDI ultra-pure water equipment system, which included the pre-treatment part, the secondary reverse infiltration part, the EDI part, the 18M water supply part, etc. Each part was placed in the water station and operated under the control of the PC. The control system of distributed control and concentrated monitoring was used to ensure the water quality and quantity of ultra-pure water. Throughout the entire process, the daily tap water first entered the original water storage tank. After a series of treatments, it was filtered through the secondary ro reverse infiltration and entered the EDI module and the polishing mixed bed module. The EDI produced water entered the high-purity water storage tank, and then after subsequent treatment, it reached different electrical resistance requirements and was sent to the water point. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-05 01:52

The backwater pressure is greater than the water supply, causing the pump to reverse.

The return water pressure is greater than the supply water, which may cause the pump to reverse. When there is such a pressure difference, it may cause the pump outlet check valve to be loose, causing the medium to flow backward and cause the pump to reverse. Once the water pump is found to be reversed, the position of two phases can be changed to change the direction of the water pump for the water pump driven by the three-phase motor; if it is a water pump driven by a single-phase motor, the position of the contact can be changed. At the same time, if the pump reversed, it was necessary to pay attention to the possible harm, such as the sharp drop in the pressure of the outlet main pipe, the friction between the moving and static parts of the pump caused by the loosening of the impellers, the damage of related components, the lower the head, or even the inability to produce water. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-11-19 01:43

Shanxi high quality ro reverse infiltration equipment price

Generally speaking, the price of reverse infiltration equipment in Shanxi differed due to factors such as water production, application, and water standards. For example, the price of commercial reverse infiltration water treatment equipment with a water yield of 0.5 - 10T/H was about 12,000 yuan; the preferential price of 10 tons of single-stage reverse infiltration industrial pure water equipment was about 159,000 yuan; the price of 1 ton and 2 tons of circulating water equipment in Tawang Deionized Water Treatment Equipment Plant was 21,000 yuan. But overall, the price ranged from tens of thousands to hundreds of thousands. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-02 06:59

Modern hydraulic pump feedback pressure

The value of the feedback pressure of a modern hydraulic pump varies due to factors such as the type of hydraulic pump. For the high-pressure hydraulic pump, the normal value of the feedback pressure is usually between 300 - 500 psc, but it needs to be adjusted and optimized according to the load capacity of the system; the normal value of the feedback pressure of the small power pump can be set between 200 - 400 psc, depending on the size of the pump, the speed and the type of pressurizing valve; The normal value of the feedback pressure of the series planetary hydraulic motor is usually 40 - 50 psc to ensure the stable operation of the axial-loading and ball-drive system. At the same time, the pressure of the hydraulic pump will be fed back to the pump through the load sensing valve. The output pressure is generally slightly greater than the maximum load pressure, and the degree of the pressure is determined by the pressure difference valve on the pump, usually 20 - 30bar. In addition, the normal value of the feedback pressure of the hydraulic pump also depends on the design parameters of the hydraulic system and the environment of use. Different pump types, the standard parameters corresponding to the hydraulic valve and the intermediary oil may also be very different. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-11-20 12:02

What does the reverse arrangement of the high-pressure cylinder mean?

The reverse arrangement of the high-pressure cylinder was mainly to balance the thrust. Since the steam impulse would generate an axial-direction thrust, the high-pressure and intermediate-pressure cylinder could offset this axial-direction thrust to a certain extent by adopting the reversed arrangement. In addition, in some steam turbine structures, the high and medium pressure stages adopt reaction blades, which will lead to a large thrust. In order to balance the large thrust on the rotor-side, in addition to adopting the reverse arrangement of high and medium pressure on the flow passage part and the inclined hole on the governing stage impellers, the rotor-side is also equipped with balancing piston-like measures. Through these methods, the steam turbine can operate safely and stably. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-24 21:20

Low cost of Hetian reverse infiltration

Based on the available information, it was impossible to understand the exact meaning of the statement "Hetian's reverse infiltration costs are low". If the "Hetian" here referred to the Hotan Prefecture of Xinjiang, the price of the reverse infiltration membrane in Hotan Prefecture could range from 240 yuan to 450 yuan. As for the reverse infiltration water treatment equipment, its price was determined according to the application field, water consumption standard and water consumption, ranging from tens of thousands to millions. As for the reverse infiltration scale inhibition agent, no special expenses related to Hotan Prefecture were mentioned. There was not enough data to compare the reverse infiltration-related costs in the Hotan Prefecture with other areas. If it was said that the cost of reverse infiltration in Hotan Prefecture was low, but it was not clear whether it was equipment cost, scale inhibition agent cost or other related costs, it was difficult to answer accurately. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-10 03:25

Yuxi industrial reverse infiltration equipment

There was no detailed information on the industrial reverse infiltration equipment in Yuxi. He only mentioned that there were trading activities related to reverse infiltration water purification equipment in Yuxi, Yunnan, such as shipping to customers in Yuxi, and that there were companies in Yuxi that needed water purification equipment (President Li, who made tap water). No more targeted information about the characteristics and usage of Yuxi Industrial Reverse Osmosis Equipment was obtained. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-12 22:38

Two-level reverse infiltration problem

Secondary reverse infiltration was a technique that used pressure to force water molecules to pass through a reverse infiltration membrane that had a selective permeating effect on water molecules. According to the different osmic pressures of various materials, the device can separate, extract, purify, and concentrate by reverse infiltration, which is greater than the osmic pressure. It can remove more than 98% of the dissolved salt and more than 99% of the colloid, microorganisms, particles, and organic matter in the water. It is the best equipment for modern pure water and space water (ultra-pure water) projects. The second-stage reverse infiltration equipment consisted of a two-stage Reverse Osmosis device, a cleaning system, and a middle water tank. In the operation process, the raw water was first sent to the pre-treatment system for rough filtering, and then filtered by the precision filter. After being sent to the first-stage reverse infiltration system by the first-stage high-pressure pump, the water produced by the system was then sent to the second-stage reverse infiltration system by the second-stage high-pressure pump to produce product water (pure water). <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-18 15:08

Intelligent reverse infiltration water purifier

The intelligent reverse infiltration water purifier was a high-efficiency water purification equipment. It used reverse infiltration technology to effectively remove dissolved solid, bacteria, viruses, heavy metals and other impurities in the water, thus providing almost pure drinking water. This type of water purifier was usually equipped with a multi-stage filter element. The common ones were PC cotton, activated carbon, and a membrane to ensure that the water quality was optimal. Its multi-stage filter system could filter the water layer by layer. The fiber cotton filter could filter large particles of impurities, the activated carbon filter could absorb odor and residual chlor, and the RO membrane was the core filtering component. Intelligent functions were one of the main features of the intelligent reverse infiltration water purifier. It often had intelligent monitoring functions, such as smart Wi-Fi connection, mobile phone remote control, filter life reminder, and so on. This allows the user to easily grasp the working state of the water purifier at any time, and know whether the filter needs to be replaced in time, increasing the convenience of use. In terms of design, most of the wading components of the modern intelligent reverse infiltration water purifier were made of food grade or bis-A-free safety materials, which not only guaranteed the health of users, especially children, but also pursued simplicity and fashion in design. It was easy to install under the kitchen cabinet and did not take up additional space. In addition, some intelligent reverse infiltration water purifiers had high energy efficiency and low waste water discharge design, which met the requirements of modern society for energy conservation and reduction. Some high-end models could also provide large amounts of water to meet the needs of many people in the family. Well-known brands of smart reverse infiltration water purifiers usually provide professional installation services and regular maintenance to ensure long-term stable operation of the product. Moreover, as the technology matured and market competition intensified, its cost-performance ratio became higher. It was not only suitable for families, but also for offices, schools, and other places to meet the needs of different user groups. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-03 03:13
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z