webnovel
Reverse Osmosis Non-Oxidizing Bactericide

Reverse Osmosis Non-Oxidizing Bactericide

2026-11-16 17:25
1 answer

Reverse Osmosis Non-Oxidizing Bactericide has the following characteristics: 1. ** Principle of sterilization **: It is not to kill microorganisms by oxidization, but to make the poison act on the special parts of the microorganisms, which are not affected by the reducing substances in the water. 2. ** Common type **: It is usually a non-oxidiser compound of the class of chloride-based and quarternary-based compounds, such as diclorphene, dicyanodimethane, thiazolin,(1227, benzalkinium, germine), and dodecyldibromide-based (benzalkinium, germine), etc. 3. ** Function and characteristics ** - ** Permanence of killing effect **: Has a certain degree of persistence. It has penetration and stripping effects on deposits or slime. It is less affected by reducing substances such as hydrogen sulfureted and nitrogen. It is less affected by the pH value of water. - ** Membrane compatibility **: It is compatible with all membranes. - ** Range of application **: A wide range of suitable pH. It has good biochemistry and does not pollute the environment. - ** Disadvantages **: The treatment cost is higher than that of the disinfectant, which is easy to cause environmental pollution, and the microorganisms in the water are easy to produce anti-drug dosage forms. 4. ** Usage Method ** - ** Adding Method **: - ** Continuous dosage **: During the operation of the reverse infiltration system, the dosage is continuously added through the measuring pump. The dosage concentration is generally 1 - 6pm, and it is diluted 10 times with the de-salted water. - ** Intermittent dosage **: During the operation of the reverse infiltration system, the dosage will be intermittently added through the measuring pump. The dosage will be added once every 5 - 7 days, and the dosage will last for 30 - 60 minutes each time. The dosage concentration will be 300 - 400pm. - ** Steps (Take a company's product as an example)**: - ** Confirm injection point **: According to the design and operation of the reverse infiltration system, choose to inject the disinfectant between the outlet pipe of the reverse infiltration system and the pre-filter closest to the reverse infiltration membrane. - ** Calculating dosage **: Calculating the correct dosage according to the scale of the reverse infiltration system and the concentration requirements of the disinfectant. - ** Dissolving disinfectant **: Add disinfectant powder or liquid into a certain amount of water and dissolve it fully with a stirring device. - ** Inject disinfectant **: Inject the dissolved disinfectant into the injection point of the reverse infiltration system through the pump and other equipment. The injection speed should be appropriate to prevent the sudden change of pressure in the water pipe from affecting the operation of the system. - ** Test effect **: Pay attention to the operation and water quality of the reverse infiltration system after adding it, and confirm whether the concentration and efficacy of the disinfectant meet the requirements. It is generally recommended to regularly test the water sample of the reverse infiltration system, as well as the cleaning cycle and replacement cycle of the reverse infiltration membrane. 5. ** Item example (ES - 301)** - ** Performance and usage **: It has a strong penetrating ability for the cells of microorganisms, and has a decomposing and damaging effect on the cell tissues of microorganisms. It has a strong killing and inhibition effect on microorganisms such as bacteria, fungi, and algae in the reverse infiltration equipment, and has a certain stripping effect on the slime formed by bacteria. - ** technical specifications **: Appearance is blue-green transparent liquid, with a PH (original solution) of 3.5 + 1, specific gravity (20 ° C g/cm 3) of 1.03 + 0.02. 6. ** Effect **: It can penetrate the microorganisms, decompose and destroy the microorganisms, kill and suppress the microorganisms. It can be used for membrane protection. It can protect the membrane system when the equipment is shut down. It is mainly used in the pre-treatment stage and directly acts on the membrane stage. It can also be used at any point of the membrane system. It can also be used for circulating chemical cleaning. The dosage can be selected according to the actual biological pollution of the system. Read more exciting novels for free

Reverse Osmosis Membrane Non-Oxidative Protective Film

The non-oxidiser disinfectant can be used to protect the reverse permeate membrane in the membrane system. This type of disinfectant had many properties: 1. ** Bactericidal property ** - It has a special effect of high efficiency, broad spectrum, and fast speed. It can penetrate the cells of microorganisms, decompose and destroy the cells of microorganisms. It has a strong killing and inhibition effect on microorganisms such as bacteria, fungi, and algae. It also has a certain stripping effect on the mucus formed by bacteria. - For example, Fion's FN - 802 Non-Oxidative Reverse Osmosis Membrane Bactericide could quickly kill bacteria with a low dosage and had a broad-spectrum sterilization effect. 2. ** Harmonization and environmental friendliness ** - It is compatible with all membranes, suitable for a wide range of pH. It has good biodegrade properties, no pollution to the environment, and can be quickly degraded into relatively non-toxic products. For example, some non-oxidiser biochemicals are suitable for a variety of reverse permeate membranes, TFC membranes, and nanofilter membrane components such as Tao and Hyde. 3. ** The flexibility of usage ** - Can be added continuously, intermittently or used together with cleaning agents. It can be pulsed at any point in the membrane system and can also be used for chemical cleaning. - For example, continuous dosage, during the operation of the reverse infiltration system, the dosage is continuously added through the measuring pump. Generally, the dosage concentration is 1 - 6pm, and it is diluted 10 times with the de-salted water. Intermittent dosage, once every 1 - 2 days, each dosage is 30 - 60 minutes, and the dosage concentration is 300 - 400pm. Some products should be tested and analyzed when they are used, and the dosage should be determined according to the water quality test results, the type of membrane, and the working conditions of the equipment. The dosage point is recommended to pre-treat the back end of the raw water pump in the front section. The dosage method is to continuously add 3 - 10pm by the measuring pump. The dosage and dosage frequency are determined by factors such as the degree of microorganisms pollution and control requirements. It can also be diluted with the produced water of the Reverse Ion Refinement System or the de-salted water, and the diluted multiple should not exceed 10. The use of these non-oxidisers helps to protect the reverse infiltration membrane and prevent the membrane from being contaminated by microorganisms, thereby prolonging the life of the reverse infiltration membrane, improving the water yield and water quality of the membrane, prolonging the cleaning cycle of the membrane, and reducing the production cost of the enterprise. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-04 02:59

Fengzhen Reverse Osmosis

According to the information retrieved, the content about the reverse infiltration equipment in Fengzhen mentioned that the product center included reverse infiltration equipment, and listed various reverse infiltration equipment-related products such as Fengzhen's all-stainless steel double-grade 6-ton reverse infiltration equipment, Fengzhen's fully automatic 8-ton industrial reverse infiltration equipment, Fengzhen's fully automatic 7-ton stainless steel industrial reverse infiltration equipment, etc. These products involved helping customers win the bid for reverse infiltration equipment and ultra-pure water equipment projects, and providing nationalized services. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-02 19:28

Reverse Osmosis System

Nanoflot was a pressure-driven membrane separation process between reverse infiltration and ultrafiltration. The pore size of the membrane was about a few nanometres, and it could block substances with a size of about 1 nanometre (about 200 - 400 molecular weight). Reverse Osmosis was the finest membrane separation technology. The membrane filter diameter was up to 0.1 nanometres. It could allow water molecules to pass through while blocking all dissolved salt and organic substances with molecules greater than 100. In terms of efficiency, the nano-filter's filtering effect was between that of the ultra-filter system and the reverse infiltration system. In terms of the scope of application, nanofiltration was more used to treat surface water, well water, or places where the purity of the produced water was not too strict. The energy consumption was also lower than that of reverse infiltration. Due to the excellent filtering accuracy of reverse infiltration systems, they were mostly used in industrial pure water manufacturing, pure water manufacturing, hospital ultra-pure water manufacturing, and other places with high requirements for water standards. Both the nanofiltration and reverse infiltration systems could use reverse infiltration scale inhibition agents, which could prevent the membrane surface from scaling, improve the water yield and water quality, and reduce operating costs. In addition, Arkema PVP 761/761A can be used to produce nano-membranes and reverse infiltration membranes. These membranes can be used to remove suspended matter, bacteria, particles, and other metal impurities in water. They are widely used in drinking water treatment, waste water recycling, industrial water treatment, seawater desalination, mineral water treatment, and high-purity water production. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-06 06:16

Reverse Osmosis Equipment

Reverse Osmosis equipment in daily life was a kind of membrane separation technology equipment that used pressure as the driving force with the help of a pervious (semi-pervious) membrane. When the applied pressure is greater than the permeate pressure of the feed water solution, the water molecules penetrate the membrane and flow out through the water production channel and the back end of the central tube to achieve separation and purification. This equipment could use membrane separation technology to effectively remove charged ions, minerals, colloid particles, bacteria, and organic substances in the water. It uses a reverse infiltration membrane (Reverse Osmosis membrane) with a very small pore size (1/10000 um, equivalent to 1/6000 of the size of E. Coli, 1/300 of the virus) to turn high-concentration water into low-concentration water. It can isolate industrial impurities, heavy metals, bacteria, viruses, and other impurities mixed into the water, so as to meet the physical and chemical indicators and hygiene standards stipulated for drinking, and produce pure water. Its advantage lies in the deep removal of all kinds of impurities, heavy metal ions, bacteria, viruses and other substances in the water, so that the water quality reaches the standard of pure water. It is the best choice for the preparation of high purity water, the desalination of brackish water and the treatment of waste water. The water purifier commonly used in daily life is also often used in food factories, pharmaceutical factories, hospitals and other industries to meet the high requirements of these industries for water quality. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-12 12:39

Where is the Reverse Osmosis filter?

In a common household reverse infiltration five-stage water purifier, the reverse infiltration membrane filter was located behind the first two filter elements (the fiber cotton filter and the activated carbon filter). Generally speaking, the layout order of the water purifier filter element was as follows: the first stage of the filter element was the first filter element to filter the raw water to remove coarse particles, colloid suspended substances, etc.; the activated carbon filter element was located behind the filter element, which absorbed the odor, organic matter, some heavy metals, etc. in the water; then there was the Reverse Osmosis membrane filter element, which had a pore size of 0.0001 um and could effectively remove organic impurities in the water; followed by the rear activated carbon filter element, which was used to suppress the regeneration of bacteria, improve the taste, and make it sweet to the mouth. In addition, some advanced water purifiers may contain other types of filter elements, such as a violet lamp, a compressed carbon filter element, etc., but the position of the Reverse Osmosis membrane filter element is usually in the above order. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-07-02 12:29

Reverse Osmosis Equipment in Yunnan

The following is a possible configuration scheme for the reverse infiltration equipment in Yunnan: 1. ** Pre-processing Part ** - ** Original Water Tank **: It is used to store raw water and ensure stable water intake for subsequent equipment. - ** raw water pressurizing pump **: provides enough pressure for the raw water to pass through the subsequent filtering equipment. - ** Quartz sand filter **: It can effectively filter the larger particles of impurities in the water, such as sand, etc. Its filtering effect is better, and it is important to protect the key components of the subsequent equipment (such as the membrane). - ** Activated carbon filter **: The absorption effect of imported coconut shell activated carbon is excellent, more than 5 times that of ordinary activated carbon. It can effectively absorb impurities such as odor and organic matter in water, further purify water quality and protect the service life of the membrane. - ** Fully automatic water conditioner (option)**: Can be used when the hardness of the raw water is high. It is used to remove the calcium and calcium ions in the water and reduce the hardness of the water. - ** Security filter **: The final rough filtering of the water entering the Reverse Osmosis host to prevent large particles of impurities from entering the Reverse Osmosis host and protect the Reverse Osmosis membrane. 2. ** Core Part-Reverse Osmosis Host ** - ** Reverse Osmosis Membrane Element **: The imported high-precision Tao Reverse Osmosis Membrane can be selected. Its filtering precision can reach 0.0001 um. It can effectively remove various salt and impurities and achieve ultra-fine filtering of raw water. - ** High-pressure pump **: It provides the high pressure needed for the reverse infiltration process to promote the separation of water through the Reverse Osmosis membrane. For example, the Southern vertical pump can meet the operating pressure requirements of the equipment. 3. ** Post-processing (selected according to requirements)** - ** Pure Water Tank **: It is used to store the pure water produced by the Reverse Osmosis Host. - ** Transfer pump system (option)**: Transfer the pure water from the pure water tank to the point of use. 4. ** Complete protection and control system ** - **AI Automatic Operation System **: It is equipped with safety protection devices such as water shortage protection and low pressure protection to ensure the safe and stable operation of the equipment. - ** Intelligent Water Protection System **: Makes the equipment more convenient to use. - Before the reversal process, a UV-disinfectant (for example, the treatment capacity is 17.6m3/h, the emitting wave length of the UV-lamp is 254mn, the intensity is 30000? W/cm2, and the sterilization rate is 99%) and a scale inhibition agent dosage system (for example, a Flowcon 260 is used, and the designed dosage is 2.4g/L) can be set up to ensure the stable operation of the reversal process. The UV-disinfectant can kill the bacteria in the water to prevent the reversal process membrane from being polluted, and the scale inhibition agent dosage system can prevent the condensation of the concentrated water side of the reversal process. The specific selection of equipment should be determined by factors such as water demand, raw water hardness, and applicable occasions. For example, when the hardness of the raw water is different, the equipment selection method is different. When the hardness of the raw water is less than 3m·mole/L, the time control type can be selected according to the large water production capacity of the equipment; when the hardness of the raw water is less than 6m·mole/L, the equipment can be selected according to the large water production capacity of the equipment; when the hardness of the raw water is less than 8m·mole/L, the equipment can be selected according to the average water production capacity of the equipment; when the hardness of the raw water is 8 - 10m·mole/L, it should be calculated according to the small water production capacity of the equipment, or a multi-level system should be adopted. If the hardness of raw water is greater than or equal to 10m·mole/L, multi-stage treatment must be selected. Generally, two-stage treatment can meet the requirements. There were also many types of equipment, and the models were mainly based on the water yield. They could be customized from 1 ton to 300 tons. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-04 08:01

Reverse Osmosis Cost in Xinjiang

The price of reverse infiltration equipment was affected by many factors, including brand, model, configuration, materials, application field, water standards, water consumption, etc., ranging from a few thousand yuan to hundreds of thousands of yuan or even higher. In Urumchi, the price of reverse infiltration equipment also varied greatly. For example, the price of 1 ton/hour pure water equipment (reverse infiltration equipment) was $9,800.00 (starting batch), the price of Xinjiang pure water treatment equipment (reverse infiltration water treatment unit) was $9,600.0, and the price of Xinjiang pure water treatment filtering drinking water equipment (industrial large reverse infiltration pure water machine plating factory water machine) was $29,000. However, this was only part of the price of the equipment. The actual price had to be determined according to the specific needs. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-05 20:18

Mbc881 Reverse Osmosis Agent

MBC881 was a type of reverse infiltration disinfectant. In reverse infiltration equipment, it was mainly used to suppress the content of bacteria, algae, microorganisms and other substances in the water. By destroying the tiny biological cells, the cells were decomposed and played a role. The price varies according to different sales locations and supply conditions. For example, there are different prices of 19.0 yuan, 114.0 yuan, 53.2 yuan, etc. in Shen Zhen, 1500.0 yuan in Suzhou City, and 17.1 yuan in Dacheng County. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-07 15:06

Industrial Reverse Osmosis Device

The industrial Reverse Osmosis device was a device that used a semi-transparent membrane to produce pure water from saltwater under the effect of a pressure difference. Its principle was the opposite of natural infiltration, and it was also known as reverse infiltration. It could achieve the purpose of separation, extraction, purification, and concentration by reverse infiltration, which was greater than the permeate pressure, according to the permeate pressure of different materials. The industrial Reverse Osmosis device can remove more than 97% of dissolved salt and more than 99% of colloid, microorganisms, particles, and organic matter in water. It is the best equipment for modern pure water, high-purity water, and space water (ultra-pure water) projects. It has the characteristics of low energy consumption, no pollution, simple process, high water quality and easy operation and maintenance. In industrial applications, the raw water will first be pre-treated by fine filter, particle activated carbon filter, compressed activated carbon filter, etc., and then pumped with a small pore size.(1/10000 um) Reverse Osmosis membrane, which can turn high-concentration water into low-concentration water, and at the same time isolate industrial impurities, heavy metals, bacteria, viruses and other impurities mixed into the water, so that the produced water can meet the physical and chemical indicators and hygiene standards of relevant drinking regulations, or meet the needs of industrial production (such as electronics, medicine, food, light textile, chemical, power generation, etc.) for high-purity water. During the operation, all kinds of raw water contained a certain concentration of suspended substances and dissolved substances, which may cause membrane contamination. For example, there were biological particles such as mineral salt, colloid, microorganisms, algae, etc. in suspended matter, easily dissolved salt (such as chloride-based), hardly dissolved salt (such as carbonate-based, sulfate-based, and silicite-based), metal oxide-based, acid and base, etc. in dissolved matter. Membrane pollution will lead to deterioration of system performance. For example, suspended particles deposited on the membrane will block the intake passage and increase the friction resistance (pressure drop); when the indissolvable salt exceeds the saturation limit, it will form scale on the membrane surface, reducing the flux of the membrane, increasing the operating pressure and pressure drop, and causing the product water quality to decline. In order to reduce membrane pollution, it is necessary to pre-treat the water. The effect of the pre-treatment is reflected in the reduction of the absolute value of the water quality indicators of TSS, Toc, Sludge, Bod, LSi, iron, Mn, aluminum, Si, Ba, Stronghold, and so on. In addition, it is necessary to reduce the PDI as much as possible (the ideal PDI (15 minutes) value should be less than 3). In addition, in order to improve the operational performance of the reverse infiltration system, chemicals such as acid, base, disinfectant, scale inhibition agent, and dispersing agent can also be added to the feed water. For example, adding acid (commonly used sulfuric acid or sulfuric acid) can reduce the ph and prevent the scaling of calcium carbonate; adding base (commonly used soda) can increase the ph and improve the removal rate in the secondary ro system; adding dechlorination agent can eliminate residual chlor, etc. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-08 02:30

2. Two-stage Reverse Osmosis

The quoted price of the two-stage reverse infiltration equipment was related to many factors, such as brand, specifications, production volume, etc. Generally speaking, its price ranged from a few thousand yuan to hundreds of thousands. For small families or small enterprises, the price of double-stage reverse infiltration equipment was usually between a few thousand yuan and ten thousand yuan, while the price of double-stage reverse infiltration equipment used by medium and large enterprises would be higher. For example, the price of 0.5 tons of double-stage reverse infiltration related products was 561.33 yuan, the price of 0.75 tons- 1.5 tons- 2 tons reverse infiltration equipment was 7800 yuan, the price of 4T double-stage reverse infiltration water treatment equipment was 61,000 yuan, and the price of 2 tons of double-pole water treatment equipment was 32,000 yuan. <a href="/?from=ask_words" style="color:red" target="_blank">Read more exciting novels for free</a>

1 answer
2026-09-08 17:14
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z